Structured preliminary calculations for railway-adjacent construction projects.
PUBLIC PROTOTYPE · UNVERIFIED
PUBLIC PROTOTYPE — no password protection. Do not enter confidential or sensitive project details. The software stores draft records locally in your browser, not in a central project database. Not for construction or design approval. These tools are draft geometry, quantity and screening aids. BRE BR470 design, piling capacities, ground-bearing design, railway controls and construction approvals require competent engineering assessment, validated source inputs, appropriate independent checking and project-specific certification.
Available tools
14
Preliminary calculators, research studies and assurance registers
BR470 engine
Dual-method study
Cohesive and granular research screens; licensed BR470 independent checking still required
Design sign-off
Not enabled
Printouts carry a draft watermark and require human review
Calculation library
Select a module to record a calculation and generate a branded preliminary report.
Design assurance roadmap
The expanded cohesive/granular working-platform screen and dual-combination Eurocode 7 pile screen are strictly preliminary models requiring independently verified source parameters and engineering review. The next steps are licensed BR470 design-method validation (including granular subgrades), approved Eurocode 7 UK NA factor sets, rig load-case handling, crane-mat structural design, testing and independent checking. Do not use the displayed numbers for construction or submission.
Reference management: BRE BR470 (2004), FPS Working Platforms/rig loading guidance, CPA Ground Conditions for Construction Plant, CPA CIG/TCIG 2503 (2025), Network Rail CIV/0063 Issue 2, and project-specific design briefs. The user must establish applicable current editions and contractual requirements.
mirello rail.DRAFT CALCULATION — UNVERIFIED
Inspect published pile worked examples
PUBLISHED ARITHMETIC DEMONSTRATIONS ONLY. NHBC loads its historical UK example factors; the JRC 2013 single-CPT example deliberately loads generic European (CEN) factors, NOT UK National Annex factors. Neither is a verified project design. Never copy coefficients into site calculations.
SLS source discrepancy: NHBC G2 prints 9.2 mm, but its stated settlement equation and load split produce approximately 10.2 mm. The demo reports the independent calculation rather than concealing the difference.
Explore characteristic resistance examples
PUBLIC ARITHMETIC DEMONSTRATIONS ONLY. UK factors are applied to the JRC four-static-test example and, separately, to four published Bauduin CPT-derived resistances from 2002. The third profile dataset is synthetic. The original examples used non-UK factors, so their published characteristic results will differ from UK re-evaluations. These are arithmetic comparisons, not UK National Annex-approved project designs.
UK source benchmark: Bond & Harris Example 13.4 reports approximately 857 kN characteristic resistance, 77% DA1 C1 utilisation and 101% DA1 C2 utilisation. Combination 2 fails. The source provides resistances at a 6 m pile toe, not fully digitised CPT curves needed to independently derive a design pile length.
Illustrative multi-CPT pile-length profiles
SYNTHETIC TEST DATA, NOT A LIVE DESIGN. Two independent example CPT profiles with constant interpreted cone resistance and supplied fictional shaft/base coefficients. This button demonstrates numerical correlation arithmetic only, not an endorsed CPT design correlation, site assessment, or UK NA design check. Never reuse these coefficients without independent source calibration.
Input data
Project values and documented assumptions
Preliminary calculation · Generated · No engineering approval
Computed results
Enter values to calculate.
Design workflow and engineering checks
These steps describe what a competent engineer must consider. They do not turn the concept result into a design.
References and limitations
Calculation register · Mirello Rail
Browser-local drafts and checking notes are editable, unauthenticated records, not an approved design archive. Do not enter confidential site information while this portal remains public.
Design authorisation: Secure login, MFA and a server-controlled approver role will be required. Public prototypes cannot approve, sign or authorise a design.
Checking workflow
Draft checking register
Engineering control: These are self-entered review records. Recording a reviewer’s name or reference does not prove an independent check. Authorisation will remain locked until secure server verification of identities, permissions and calculation integrity.